JH Solar Version 1: 7 kW, 16.38 kWh All-in-One Solar Unit

Last checked · JH Solar guide

JH Solar Version 1 all-in-one solar unit, 7 kW and 16.38 kWh, with the JH Solar technician mascot

JH Solar Version 1 is a full-size all-in-one solar unit: a 7 kW hybrid inverter, a solar charger and a 16.38 kWh LiFePO4 battery, the bigger battery of our two units, in one floor-standing cabinet on casters. The unit price is ₱120,000. It is built for homes that want strong night and brownout backup at a lower price, with up to six panels on the roof.

This page covers the full specifications, how its single solar input works, what it can run, its honest limits, how it is wired and placed, and how to order. Every number is either a rated figure or a worked example labelled “Example”, with the math shown.

JH Solar Version 1 all-in-one solar cabinet with its display and logo

What JH Solar Version 1 Is

JH Solar Version 1 joins three parts that are usually sold as separate boxes: a hybrid inverter that turns battery and solar DC into 230 V AC for your outlets, an MPPT solar charger, and a lithium iron phosphate battery. Because they share one cabinet, there are no external battery cables to run between boxes, and the inverter and battery are already matched.

It is plug-and-play in that sense: the hard pairing work is done inside. It is also a floor-standing unit on casters that can be moved, which makes it the step up from a hand-carry power station. The panels still go on your roof, and a licensed electrician still connects the unit to your panel board. Our Version 1 and Version 2 comparison shows how it sits next to Version 2, which has the bigger inverter and solar input.

The unit works with or without grid power. Grid power passes through it to your house panel, and when Meralco or your electric cooperative has a brownout, it switches in about 10 ms and runs the same loads from solar and the battery.

Who JH Solar Version 1 Suits

JH Solar Version 1 suits most homes on Meralco or an electric cooperative that want strong backup at night and during brownouts. With the grid connected, it fits homes using up to roughly 500 to 550 kWh a month, as the grid covers what its six panels cannot. Its big battery is the strong point. Its single solar input, which takes up to six panels, is the part that sets the ceiling.

If you need more than about 5.6 kW running at once (several aircon units together), live off-grid and use more than about 300 kWh a month, or want the most bill savings from daytime solar, the JH Solar Version 2 with its 11 kW inverter and dual MPPT inputs is usually the better match. The quickest way to see which side you are on is to run your electric bill through our solar computation tool, which shows your daily kWh and every assumption.

JH Solar Version 1 Price: ₱120,000 for the Unit

Unit price

Regular price ₱170,000Discounted price
₱120,000

Unit only; panels, mounting, wiring, labor and permits are quoted after a site assessment.

People often ask “magkano ang JH Solar Version 1?” The unit is ₱120,000. That buys the cabinet with the 7 kW inverter, the solar charger and the 16.38 kWh battery inside. It does not include the panels or the work around them.

Full Specifications

These are the rated figures for JH Solar Version 1. Keep this table handy when you read your quote.

Version 1 specifications
ItemRating
TypeAll-in-one: inverter + MPPT solar charger + LiFePO4 battery in one cabinet
Inverter output7 kW, 230 V AC, pure sine wave
Battery16.38 kWh nominal, 51.2 V, 320 Ah, LiFePO4
Solar input4,480 W max PV input, one MPPT
MPPT voltage range60–140 V DC
Max PV open-circuit voltage180 V
Max solar charging current80 A
Panels per stringUp to 3 in series (180 V limit)
Typical array6 × 620 W in 3S2P = 3.72 kWp (6 × 720 W = 4.32 kWp)
MountingFloor-standing on casters

Dimensions and weight are confirmed with your quote. Battery kWh is nominal; the energy that reaches your appliances is lower (see the examples below).

Two numbers matter most when you plan. The 7 kW inverter rating is how much power the unit can deliver at once, and the 16.38 kWh battery is how much energy it stores. Mixing up kW and kWh is the most common sizing mistake, so read how home batteries are sized for nominal versus usable kWh.

How the Solar Input Works: One MPPT and the 3S2P Layout

JH Solar Version 1 has one solar input with one maximum power point tracker (MPPT). The tracker works between 60 V and 140 V, accepts up to 4,480 W of panel power, and must never see more than 180 V open-circuit.

Why three panels in series is the maximum

Panels in series add their voltage. Our 620 W panel is rated 48.6 V open-circuit and 41.3 V at maximum power. Three in series give about 145.8 V open-circuit and 123.9 V while working, which sits inside the MPPT window and under the 180 V limit. Four in series would reach about 194.4 V, and panel voltage climbs even higher on cool, bright mornings, so a fourth panel is never added.

Two strings in parallel

To use six panels, the installer builds two strings of three and joins them in parallel. This is called 3S2P. Parallel strings add current while keeping the voltage of one string.

Panel options for JH Solar Version 1 (one MPPT input)
LayoutPanelsArray sizeFits the input?
3S2P with 620 W panels (standard package)6 × 620 W3.72 kWpYes, under the 4,480 W input
3S2P with 720 W panels6 × 720 W4.32 kWpYes, close to the input rating
4 panels in one string4 in series—No: about 194.4 V open-circuit with 620 W panels, over 180 V
More than 6 panels7 or more—Not a standard layout; look at Version 2 instead

The 720 W panel's electrical data is confirmed with your quote. Strings must also pass the input's current limits, which your installer checks against the manual.

Roof diagram of six solar panels wired as two strings of three, joined through fuses to one solar input

The Honest Limit: Recharging 16.38 kWh From Six Panels

The battery is large, but the solar input takes only six panels, so a fully drained battery is hard to refill in one day.

Example: even if the input ran at its full 4,480 W for a 3-hour midday peak, that is 4,480 W × 3 h = 13.44 kWh, still less than 16.38 kWh. With the standard 3.72 kWp package and 20% losses, the same 3 hours give about 3.72 × 3 × 0.8 ≈ 8.9 kWh. The charging current caps out too: Example: 80 A × 51.2 V ≈ 4.1 kW into the battery at most.

Across a whole sunny day the panels give more than the peak window alone. Example: 3.72 kWp × 4 peak sun hours × 0.75 overall factor ≈ 11.2 kWh. Daytime appliances use part of that before it reaches the battery. On rainy-season days, expect less.

In practice, JH Solar Version 1 works best with the grid connected, so the grid tops up the battery between outages, or when night use leaves the battery partly charged by morning.

What JH Solar Version 1 Can Run

Two checks decide whether JH Solar Version 1 fits your loads. First, power: add up the watts of everything that runs at the same moment, plus the start-up surge of motors like a fridge compressor or aircon, and keep it under 7 kW. Second, energy: add up watts × hours for each appliance and divide by 1,000 to get kWh.

Example brownout night on Version 1
Example loadExample watts × hoursExample energy
LED lights (8 bulbs × 10 W)80 W × 6 h0.48 kWh
Two electric fans120 W × 8 h0.96 kWh
Inverter-type refrigerator (average draw)100 W × 12 h1.2 kWh
TV100 W × 4 h0.4 kWh
Wi-Fi router15 W × 12 h0.18 kWh
Example total without aircon—≈ 3.2 kWh
Add: 1HP inverter aircon800 W × 8 h6.4 kWh
Example total with aircon—≈ 9.6 kWh

Example wattages only. Use the labels on your own appliances; real draw changes with settings, heat and age.

Example: the battery delivers about 16.38 kWh × 0.9 usable × 0.95 efficiency ≈ 14.00 kWh to your appliances. Only the night counts: by day the panels run the loads and refill the battery. The night without aircon uses less than a quarter of that. The night with one aircon fits with room to spare, but six panels then need most of a sunny day to refill it.

For aircon users, an inverter-type unit set at a moderate temperature is much easier on the battery than an old non-inverter one. Our guide to solar inverter limits explains motor start-up surge. In a brownout every load on your house panel runs from the unit, so what runs at once must stay under 7 kW.

Philippine home with its lights on at night while the neighboring houses are dark during a brownout

Typical Wiring Summary

A Version 1 install follows a standard layout. This summary is for understanding your quote, not a do-it-yourself guide: the AC side and the panel board connection are work for a licensed electrician.

Electrical work in the Philippines is done by a registered master electrician or a professional electrical engineer; the Institute of Integrated Electrical Engineers of the Philippines publishes the Philippine Electrical Code they follow.

Where to Place the Unit

The battery and inverter last longer when they stay cool and dry.

Philippine Conditions and Tips on Your Phone

Peak sun hours in the Philippines are typically about 3.5 to 5 a day, depending on place and season. You can look up your own city on the Global Solar Atlas. During the rainy season, output can stay low for days, which is when grid top-ups and careful load choices matter most for a six-panel system.

Heat also matters: panels lose some output on hot afternoons, and batteries age faster when they run hot. Typhoon season calls for mounting that suits local wind and a check after a strong storm.

On your phone

How to Order JH Solar Version 1

Ordering JH Solar Version 1 follows five steps, and nothing is final until you accept a written quote.

  1. Step 1: Compute your needs

    Enter your bill’s kWh in the solar computation tool to see your daily use and a rough system size.

  2. Step 2: Send your bill

    Hide your name, address and Customer Account Number (CAN) before you take the photo; we only need the kWh used, the billing period and the amount. Then send the bill photo, your city or barangay and the appliances you run at the same time, through the form on our contact page or on Messenger.

  3. Step 3: Site assessment

    We check the roof, shade, the spot for the cabinet, the distance to your panel board and your wiring.

  4. Step 4: Written quote

    You get the unit, panel count, parts list, price and warranty terms in writing. Ask anything first.

  5. Step 5: Installation

    Licensed electricians install the panels, protection devices and unit, test it, and show you how it works.

If you would rather talk first, the contact page for quotes and site assessments lists what to send and what happens next.

Payment Methods and Warranty

Payment methods we accept: Bank transfer, GCash, Maya, Cash. The payment terms for your order are written into your quote, so you know what is due and when before you pay anything.

For Version 1, the warranty terms are written into your quote. Before you sign, ask what is covered, how a claim is made, and who you call if the display shows an error during a brownout.

JH Solar Version 1 Customer Reviews

No published reviews yet.

We publish reviews only from real JH Solar customers, with their permission, after their system has been running for a while. Already have a JH Solar Version 1? Write a review with the form below or share it on our Facebook page.

JH Solar on Facebook

Customers can share their own review with the form above; each review appears on this page after JH Solar checks it.

Safety and Electrical Reminders

  • Do not open the cabinet. The battery stays live even when the grid and the panels are off.
  • Never add a fourth panel to a string. Going over 180 V open-circuit can damage the solar input.
  • Switch off the DC isolator before anyone touches the panel wiring; panels make voltage whenever light hits them.
  • Keep the unit away from LPG tanks, water and flammable items, with open space for airflow.
  • After a flood or typhoon, do not touch wet equipment. Have a licensed electrician check the system before it is switched back on.

Solar panels make DC power whenever light hits them, and batteries hold enough energy to start a fire if they are shorted. Work on the grid side, the AC panel board or a net-metered system belongs to a licensed electrical practitioner following the Philippine Electrical Code. Our numbers are estimates, not a design or a quote.

Frequently Asked Questions

Can JH Solar Version 1 run a 1HP aircon through the night?

Yes. Its 7 kW inverter has plenty of room for an inverter-type 1HP aircon plus a fridge and lights. The battery is the real limit. Example: an aircon averaging 800 W for 8 hours uses 6.4 kWh, which is nearly half of the roughly 14.00 kWh the battery delivers to loads. Add your other night loads before you decide, and check that the panels can refill it the next day.

Why does Version 1 allow only three panels in each string?

Its solar input accepts at most 180 V open-circuit. Three 620 W panels in series give about 145.8 V at standard test conditions, and voltage rises further on cool mornings. A fourth panel would reach about 194.4 V before any cold correction, which is over the limit and can damage the charger. That is why the package uses two strings of three panels joined in parallel.

Can I connect more than six panels to Version 1?

Not as a standard layout. The single MPPT input is rated for 4,480 W, and six 720 W panels already reach 4.32 kWp, close to that ceiling. More panels would push the array past the input rating, so extra panels add cost without adding much charging. If your home needs a bigger array, Version 2 with its two MPPT inputs is the unit to look at instead.

Does the ₱120,000 price of Version 1 include the solar panels?

No. The ₱120,000 is for the all-in-one unit alone. Panels, mounting rails, PV cables, DC and AC protection, labor and permits are quoted separately after a site assessment. Your written quote lists each item so you can see what you are paying for before you agree.

Will Version 1 still work if my area loses grid power for several days?

Yes, it is rated to work with or without grid power, so the panels keep charging the battery during a long outage and the battery runs your loads at night. During several cloudy days, though, the six panels may not refill the battery each day. In a long outage, cut back to essential loads such as the fridge, lights, fans and phone charging.

How many hours can a full Version 1 battery last in a brownout?

It depends on the load. Example: 16.38 kWh × 0.9 usable × 0.95 efficiency ≈ 14.00 kWh reaches your appliances. At a steady 500 W, such as a fridge, fans, lights and a TV, that is about 28.0 hours. At a steady 1 kW it is about 14.0 hours. These are example assumptions, and real runtime changes with heat, battery age and how the loads cycle.

Conclusion: Is JH Solar Version 1 Right for Your Home?

JH Solar Version 1 packs a 7 kW inverter and a 16.38 kWh battery into one cabinet for ₱120,000, unit only. It gives you the bigger battery of our two units at the lower price, and with the grid connected it suits most homes using up to roughly 500 to 550 kWh a month. Its one real limit is the solar side: the 180 V input allows at most six panels in a 3S2P layout, so it cannot refill a fully drained battery in one short peak.

Start with your bill, check your night loads against the examples above, and send us the details for a site assessment. You can also read more about JH Solar and our other guides on the homepage.

See if Version 1 fits your home

Compute your daily kWh from your bill, then send it to us for a site assessment and a written quote.